Range / Oven

Control Panel Issues

Click on the Steps below to jump directly to that section:

Step 1
1
Check power source.
Step 2
2
Check power at connector CN1.
Step 3
3
Check power at connector CN31.
Step 4
Step
Check display for missing LED segments.

**NOTICE**

Wiring Colors, Connectors, and Pins will vary by model/product code. Always be sure to download and use the service manual for your specific model.

For Test Mode procedures use this link and input your specific model: https://lgtestmodes.com/

Step 1

Example from LSEL6331

If the Display has no lights at all. Check for your power at the terminal block or receptacle.

Step 2

If the voltage is correct at the terminal block, check for 120Vac at CN1  of the Power PCB.

Step 3

If the voltage is correct at CN1. Go to CN31 of the System PCB, and check the connection, if its good, secure, replace the Display PCB.

Step 4

If the complaint is, the display lights up but it is missing some segments, or they’re dim. Check the connections for the LED module. If they’re secure replace the LED Module.