Tap into the Sealed System. Record your High and Low run pressures, Compressor Amperage, Compressor Voltage, and Freezer / Fridge Temperatures. All these readings are needed for proper diagnosis.

 

Note:

*For Accurate Troubleshooting, the unit needs to have been running for at least 25 Minutes before gathering readings.

*All pressures given can be +/- due to variances in ambient temperatures.

 

Normal Run Pressures for R600:

LOW SIDE: 10 inHG – 15 inHG

HIGH SIDE: 45 – 60PSI

Note: “inHG” means Pressure is Running in a Vacuum